top of page

Aircurve 10 BiPAP
Machine (AutoSet)

Product Highlights:
aircurve 10 bipap machine

$1599.99

  • ResMed AirCurve™ 10 VAuto BiLevel Machine with HumidAir™ Heated Humidifier is an auto bilevel machine with a built in heated humidifier capable of self-adjusting the humidification level based on the temperature of the room.

  • Features:

  • AutoSet Algorithm

  • Built In HumidAir™ Humidifier

  • SlimLine Tubing: 15mm Diameter

  • Pressure Relief Technology

  • Vsync Leak Management

  • TiControl Feature

  • My Options Color LCD Display

  • Light Sensor

  • Advanced Data

  • AutoSet Algorithm 
    ResMed developed an advanced algorithm technology for bilevel therapy to continuously monitor breathing in order to adjust the inhalation and exhalation pressure breath by breath. Adjusting the delivered pressure based on the needs of the user increases the comfort of the therapy while maintaining an open airway.

  • HumidAir™ Heated Humidifier and Optional ClimateLineAir™ Heated Tube 
    The HumidAir™ humidifier is built into the AirCurve™ 10 machine taking up limited space on a bedside table. Easily adjust the humidification level using the My Options screen on the machine. To set the amount of moisture added to the air stream, select level 1 through 8 with 1 being the lowest level of humidification, and 8 being the highest. If humidification is not desired, turn the humidifier off entirely.

  • The ClimateLineAir™ Heated Tube can be added to the therapy system to optimize humidification. Select the "Auto" function on the AirCurve 10 VAuto to allow the Climate Control system to set for the optimum humidification with minimal rainout condensation. The system considers the temperature of the room air to deliver the optimum level of humidification. Please Note: The ClimateLineAir™ tube is 78 inches in length.

  • Pressure Relief Technology

  • EPR™: When the AirCurve™ 10 VAuto is set in CPAP Mode, the machine offers Expiratory Pressure Relief (EPR™) to help therapy feel more natural. ResMed's EPR™ feature adjusts the amount of pressure delivered during exhalation and inhalation. The feature can be turned off, or set to Level 1, Level 2, or Level 3. Level 1 is the smallest change between inhalation and exhalation, while Level 3 is the largest change in pressures.

  • Easy-Breathe: In S Mode, the machine uses Easy-Breathe technology to mimic the user's breathing pattern to help create a more familiar sleep experience.

  • Automatic Adjustments: When placed in Auto Mode only, the machine is designed to automatically adapt the pressure as needed.

  • Ramp: In CPAP Mode, this feature gradually increases the pressure in increments before reaching the prescribed pressure. This is intended to help the user acclimate to the pressure and fall asleep with greater ease. In VAuto, S, ST and T Modes, the expiratory pressure increases from the starting EPAP to the prescribed pressure.

  • Vsync Technology 
    Vsync monitors mask leaks throughout the night and compensates by adjusting the baseline pressure to maintain therapy effectiveness.

  • TiControl Feature
    The TiControl feature on the AirCurve VAuto machine monitors the pattern of inhalation and exhalation, comparing it against the TiMax and TiMin settings on the machine. Those with respiratory disorders such as COPD or obstructive lung disease may experience early or delayed changes from inspiration to expiration, referred to as cycling. The 10 VAuto BiLevel TiControl feature is designed to prevent cycling by setting a minimum and maximum time limit on inspiration. When the machine detects the user breathing which falls outside the machine settings, it will intervene to alter the timing of the delivered IPAP (inhalation) or EPAP (exhalation) pressure.

bottom of page